WinLTP
Version 3.01
Leading-Edge Features
Special Features
Special Analysis Features
Ordinary Features
Additional Features
Experimental Log
 
The Experimental Log Shows:
    1. Start/Exit WinLTP
2. Enter/Return from Seal Test (print PulseAmp, Rpipette, Rseal, Rs, Rm and Idc) *
3. When Spreadsheet is cleared, AmpFile saved, Protocol file opened/saved *
4. Start/Stop Continuous Acquisition protocol *
5. Start/Stop Main Protocol 
6. What Sweeps have occurred (T0,T1,P0,P1,AP0,AP1) 
7. Protocol flow (Loop, AvgLoop, Run, Run of Run/Else, Else of Run/Else) 
8. Evoked Single and Repeat Events
9. Enter time and solution change by keyboard input
  10. When solutions have changed using the Perfuse statement (not shown below, but see this)
and can
      Determine which Sweeps, Loops, Runs and Run/Elses to show
   

For more information see Chapter 11 in the on-line WinLTP Manual.

 


The protocol script for the Log run shown at right.



PrintToLog page determines which Sweeps, Loops, Runs and Run/Elses to show - all in this example.
 
The Experimental Log run including adding 100 uM AP5 at 30 sec.

 

 

Print out Detection, Stimulation, or All Protocol Values

Clicking on a 'Detection', 'Stimulation' or 'All' button also outputs Detection, Stimulation or All Protocol Values to the Experimental Log.  The figure below shows Detection Values (in blue) printed to the Experimental log when the ‘Detection’ button is clicked, followed by the first sweep after the Detection protocol values are printed (purple).
18:05:06.2       0.0 Start MainProtocol
18:05:06.7       0.5   Enter Loop0
18:05:06.7       0.5     09200227.P0, First Loop sweep
""
18:05:23.7        "" Detection Protocol Values
""                ""     AD0
""                ""       LowPass Filter - Not used
""                ""       Rs not calculated
""                ""       S0
""                ""         Baseline: 8 to 2 ms before pulse
""                ""         Peak: Auto 0 to 15 ms before pulse
""                ""         MaxSlope: 2 ms,
-2 to 2 ms after pulse
""                ""       S1
""                ""         Baseline: 8 to 2 ms before pulse
""                ""         Peak: Auto 0 to 15 ms before pulse
""                ""         MaxSlope: 2 ms,
-2 to 2 ms after pulse
""                ""     AD1
""                ""       LowPass Filter - Not used
""                ""       Rs not calculated
""                ""       S0 - Not used
""                ""       S1 - Not used
18:05:26.7      20.5     09200231.P0, First sweep after Protocol values printed
18:05:46.7      40.5   Leave Loop0
18:05:46.7      40.5 Stop MainProtocol